Coordinated protection
The coordination study and the relay settings come with the supply, verified on a simulator.
Capabilities
01Engineering and designStudies, FEED and detailed engineering02InfrastructureConstruction, installation and commissioning03Operations and maintenanceContracted asset availability04Digital transformationTelemetry, data and operating systems05Strategic consultingCapital and capacity decisions06Systems and equipmentIn-house manufacturing and specified equipment
Transforming critical operations at regional scale
A logistics operator running six terminals across three countries was moving freight on systems that did not talk to each other. We redesigned the operation of the entire corridor and instrumented it point by point.
See moreCatalogue
01AX-360 SeriesProcess pumping02TC-200 PanelControl and automation03SK-500 SkidModular assembliesAX-360 Series
Skid-mounted single-stage centrifugal pump, sized for continuous duty at altitudes and temperatures outside the standard catalogue range.
See moreAnalysis and reports
Papers from the technical team on capacity, continuity and measurement.
See moreMedium and high voltage
Pre-assembled 138 kV line bay
A complete line bay — steelwork, switchgear, protection and earthing — delivered as a single supply with engineering and coordination included.
Buying a bay in pieces means somebody has to integrate it, and that somebody ends up being the client. Here the protection coordination arrives with the equipment.
01 / 04Specifications
The coordination study and the relay settings come with the supply, verified on a simulator.
Wind, seismic and the local pollution level go into the calculation, not a generic case.
The sequence is planned so the outage is limited to the final connection.
Integration with the dispatch centre tested at works against the client's own protocol.
02 / 04Specifications
| Rated voltage | 138 kV |
|---|---|
| Rated current | 1 250 / 2 000 A |
| Breaking capacity | 31,5 / 40 kA |
| Insulation level | 650 kV BIL |
| Configuration | Single busbar, double busbar or breaker-and-a-half |
| Protection | Distance, line differential, overcurrent |
| Telecontrol | IEC 61850 / DNP3 |
| Standard | IEC 62271 |
03 / 04Downloads
In this demo, downloads open the contact form: a real catalogue would serve the PDF here, gated or ungated depending on commercial policy.
04 / 04Quotation
No shopping cart: price depends on volume, Incoterm and lead time. Send us the operating conditions and you will receive a technical and commercial proposal.